Dental Materials
Volume 25, Issue 8 , Pages 960-968, August 2009

Operator vs. material influence on clinical outcome of bonded ceramic inlays

  • Roland Frankenberger

      Affiliations

    • Dental Clinic 1 - Operative Dentistry and Periodontology, University Medical Center Erlangen, University of Erlangen-Nuremberg, Glückstraße 11, 91054 Erlangen, Germany
    • Corresponding Author InformationCorresponding author. Tel.: +49 9131 8534251; fax: +49 9131 8533603.
  • ,
  • Christian Reinelt

      Affiliations

    • Private Practice, Nuremberg, Germany
  • ,
  • Anselm Petschelt

      Affiliations

    • Dental Clinic 1 - Operative Dentistry and Periodontology, University Medical Center Erlangen, University of Erlangen-Nuremberg, Glückstraße 11, 91054 Erlangen, Germany
  • ,
  • Norbert Krämer

      Affiliations

    • Department of Pediatric Dentistry, University Medical Center Carl Gustav Carus, Fetscherstraße 74, 01307 Dresden, Germany

Received 29 July 2008; received in revised form 20 November 2008; accepted 10 February 2009.

Abstract 

Objective

The aim of the present study was to clinically evaluate the suitability of Definite Multibond and Definite ormocer resin composite for luting of Cergogold glass ceramic inlays in a two-center trial involving two dentists.

Methods

Thirty-nine patients received 98 Cergogold inlays with at least one inlay luted with Definite Multibond/Definite (n=45) and at least one inlay luted with Syntac/Variolink Ultra (n=53) in a split mouth design. Treatments were carried out in two private practices by two operators (Operator A: n=38; Operator B: n=60). Forty-four cavities required caries profunda treatment, 23 cavities exhibited no enamel at the cervical margin. At baseline (2 months), and after 6, 14, 27, and 51 months of clinical service, the restorations were investigated according to modified USPHS criteria.

Results

The drop-out rate was 3% after 4 years. After 48 months of clinical service, 21 restorations in 16 patients (9 luted with Definite, 12 with Variolink; 2 placed by operator A and 19 by operator B) had to be replaced due to inlay fracture (n=11), tooth fracture (n=4), hypersensitivities (n=3), or marginal gap formation (n=3). Seventy-seven inlays were in good condition (survival rate 89.9%, median survival time 4.2 years (95% confidence interval ±0.25; survival analysis by Kaplan–Meier algorithm). Survival rate after 4 years was 97.4% for operator A, and 75.4% for operator B (p=0.002; Log Rank/Mantel-Cox) resulting in annual failure rates of 0.6% and 6.2%, respectively. The operators did not differently judge the clinical behaviour of the luting procedures (Mann–Whitney U-test, p>0.05). Independent of the operator and the used luting system, the following criteria significantly changed over time: color match, marginal integrity, tooth integrity, inlay integrity, sensitivity, hypersensitivity, and X-ray control (p<0.05; Friedman test). Significant differences between operators over the whole period were computed for the criteria marginal integrity, tooth integrity, and inlay integrity (p<0.05, Mann–Whitney test). Differences between luting materials were only present during single recalls.

Significances

For luting of ceramic inlays, only slight differences between the two luting systems were detectable. The operator influence on clinical outcome was clearly proven.

Keywords: Glass ceramics, Clinical trial, Operator, Adhesives, Bonding

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(09)00124-9

doi:10.1016/j.dental.2009.02.002

Dental Materials
Volume 25, Issue 8 , Pages 960-968, August 2009