Abstract 

Objective

To analyze differences in the way dental materials digitize on a non-contacting laser profilometer (NCLP).

Methods

Three Type IV dental stones and 15 impression materials were mixed according to the manufacturer's instructions and expressed against a glass block to record its surface characteristics. From each material an area of 6×40mm was scanned on the NCLP and the Ra, Rq and Rt roughness values measured from 20 randomly selected transverse profiles. The surface of the impression materials was subsequently poured in Moonstone™ (Bracon Ltd., Etchingham, England) dental stone and the same roughness values obtained from these casts. Differences in roughness values from the dental materials were compared using ANOVA and differences in roughness between impression materials and the Moonstone™ casts compared using paired t-tests.

Results

There were significant differences in roughness values between individual materials within each type (impression material or dental stone) (p<0.05). The roughness of the dental stones varied between Ra=0.87 and 0.99μm, Rq=1.09 and 1.23μm, and Rt=5.70 and 6.51μm. The roughness values of the impression materials varied between Ra=0.75 and 4.56μm; Rq=0.95 and 6.27μm and Rt=4.70 and 39.31μm. Darker materials showed higher roughness values compared to lighter materials (p<0.05). The roughness of the Moonstone™ casts varied between Ra=0.80 and 0.98μm; Rq=1.01 and 1.22μm, and Rt=5.04 and 6.38μm. Roughness values of some impression materials were statistically significantly lower when the surface was reproduced in Moonstone™ (p<0.01).

Significance

Digitization of dental materials on optical profilometers was affected by color and transparency.

Keywords: Surface roughness, Non-contacting laser profilometry, Impression materials, Dental stones

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(08)00253-4

doi:10.1016/j.dental.2008.10.003

Dental Materials
Volume 25, Issue 4 , Pages 500-505, April 2009