- . Long-term clinical success of all-ceramic posterior restorations. Quintessence Int. 2002;33:415–426
- . Buonocore Memorial Lecture. Review of the clinical survival of direct and indirect restorations in posterior teeth of the permanent dentition. Oper Dent. 2004;29:481–508
- . Longevity and clinical performance of IPS-Empress ceramic restorations—a literature review. J Can Dent Assoc. 2002;68:233–237
- . Adhäsiv und konventionell befestigte Empress 1-Kronen. Dtsch Zahnärztl Z. 2000;55:326–330
- Lehner C, Studer S, Schärer P. Seven-year results of leucite-reinforced glass-ceramic crowns. J Dent Res (Spec Iss) 1998;77:Abstract 1368.
- . An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: a retrospective study. Quintessence Int. 2002;33:503–510
- . Clinical evaluation of all-ceramic crowns. J Prosthet Dent. 2002;87:189–196
- . Survival rates of IPS Empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study. Quintessence Int. 2006;37:253–259
- . Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies. Clin Oral Investig. 2000;4:25–30
- . Influence of cyclic loading and luting agents on the fracture load of two all-ceramic crown systems. J Prosthet Dent. 2004;92:551–556
- . Fracture strength of 5 different all-ceramic crown systems. Int J Prosthodont. 1998;11:602–609
- Malament KA, Grossman DG. Bonded vs. non bonded Dicor crowns: Four years report. J Dent Res (Spec Iss) 1992;71:Abstract 1720.
- . Survival of glass-ceramic materials and involved clinical risk: variables affecting long-term survival. Pract Proced Aesthet Dent. 2003;(Suppl.):5–11
- . IPS Empress crown system: three-year clinical trial results. J Calif Dent Assoc. 1998;26:130–136
- . Clinically relevant approach to failure testing of all-ceramic restorations. J Prosthet Dent. 1999;81:652–661
- . Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures. Dent Mater. 2006;22:176–182[Epub 2005 Jul 21]
- . Fracture resistance of different partial-coverage ceramic molar restorations: An in vitro investigation. J Am Dent Assoc. 2006;137:514–522
- . In-Vitro-Testverfahren zur Evaluation dentaler Restaurationssysteme Korrelation mit In-vivo-Resultaten. Schweiz Monatsschr Zahnmed. 1990;100:1445–1449
- . Ceramics in restorative and prosthetic dentistry. Annu Rev Mater Sci. 1997;27:443–468
- . Factorial analysis of variables influencing stress in all-ceramic crowns. Dent Mater. 2006;22:125–132[Epub 2005 Jul 5]
- . Investigation of the dry and wet fatigue properties of three all-ceramic crown systems. Int J Prosthodont. 1998;11:255–262
- . The fracture resistance of all-ceramic crowns on supporting structures with different elastic moduli. Int J Prosthodont. 1993;6:462–467
- . Fracture strength of all-ceramic crowns with varying core elastic moduli. Aust Dent J. 2000;45:103–107
- . Feedback control during mastication of solid food textures—a clinical-experimental study. J Prosthet Dent. 1998;80:330–336
- . Effect of sample thickness on bite force studied with a multiple-point sheet sensor. J Oral Rehabil. 2004;31:327–334
- . Occlusal forces during chewing and swallowing as measured by sound transmission. J Prosthet Dent. 1981;46:443–449
- . Quantitative study of bite force during sleep associated bruxism. J Oral Rehabil. 2001;28:485–491
- . Effects of sample hardness on human chewing force: a model study using silicone rubber. Arch Oral Biol. 2004;49:805–816
- . Development of an artificial oral environment for the testing of dental restoratives: bi-axial force and movement control. J Dent Res. 1983;62:32–36
- . Damage accumulation and fatigue life of particle-abraded ceramics. Int J Prosthodont. 2006;19:442–448
- . Fixed partial dentures: all-ceramics, fibre-reinforced composites and experimental systems. J Oral Rehabil. 2003;30:873–877
- Eschbach S, Koutayas S, Kern M. Fracture strength of resin-bonded all-ceramic fixed partial dentures. J Dent Res 2005 (Spec Issue A):Abstract No. 430.
- . Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns. J Prosthet Dent. 2006;95:117–123
- . Fracture surface analysis of dental ceramics: clinically failed restorations. Int J Prosthodont. 1990;3:430–440
- . Fracture surface characterization of clinically failed all-ceramic crowns. J Dent Res. 1994;73:1824–1832
- Ivoclar-Vivadent (2004). IPS Empress—Scientific Documentation.
- Ivoclar-Vivadent (2007). IPS e.max Press—Scientific Documentation.
PII: S0109-5641(08)00061-4