Dental Materials
Volume 24, Issue 10 , Pages 1352-1361, October 2008

Fracture frequency of all-ceramic crowns during dynamic loading in a chewing simulator using different loading and luting protocols

  • S.D. Heintze

      Affiliations

    • R&D, Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein
    • Corresponding Author InformationCorresponding author. Tel.: +423 235 3570; fax: +423 233 1279.
  • ,
  • A. Cavalleri

      Affiliations

    • R&D, Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein
  • ,
  • G. Zellweger

      Affiliations

    • R&D, Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein
  • ,
  • A. Büchler

      Affiliations

    • Murten, Switzerland
  • ,
  • G. Zappini

      Affiliations

    • R&D, Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein

Received 10 September 2007; accepted 11 February 2008.

Abstract 

Objective

The purpose of this laboratory study was to compare the frequency of failures (complete fractures or partial cracks) of molar crowns made of two different all-ceramic materials during dynamic loading in a chewing simulator, as well as the fracture load when subjected to static loading, in relation to different dynamic loading and luting protocols.

Methods

One hundred and forty-four molar crowns fabricated with IPS Empress or an experimental e.max Press material with high translucency (e.max Press Exp) were luted on CAD/CAM milled PMMA abutments (first lower molar, circular chamfer) either with Variolink or glass-ionomer cement (GIC). All crowns were loaded according to three different loading protocols (n=12 per group) and two force profiles (sinusoidal, rectangular) in a pneumatically driven chewing simulator with a steel stylus (Ø 8mm) and they underwent simultaneous thermocycling (5°C/55°C). After each phase the crowns were evaluated with regard to fractures or cracks. After dynamic testing, the crowns that did not fail were subjected to compression loading until complete fracture in a universal testing machine (UTM). As control groups, unloaded crowns were also subjected to a UTM. Survival statistics with log-rank tests were applied for the results of the dynamic loading, while ANOVA with post hoc Tukey B was used for the fracture load results and two-way ANOVA was carried out for logarithmically transformed data. Weibull statistics were calculated for pooled fracture load data of the dynamically loaded and control groups.

Results

In the 144 IPS Empress crowns, complete fractures were observed in 9 crowns and partial cracks in another 3 crowns. When the data was pooled, a statistically significant increase in fractures occurred when the sinusoidal force profile was applied compared to a rectangular force profile (log-rank, p<0.05). No fractures occurred in the e.max Press Exp crowns. The two-way ANOVA showed that the type of luting protocol used had the most significant effect on the fracture load of both materials. In conjunction with Empress, however, the luting material influenced the variability twice as much as in e.max Press Exp. There was no statistically significant difference in the fracture load of GIC-luted e.max Press Exp crowns and that of the Variolink luted Empress crowns. The force profile had a significant effect on the fracture load only of the Empress crowns but not of the e.max Press Exp crowns. Weibull statistics revealed a higher scattering of the data of dynamically loaded crowns compared to that of the control groups.

Conclusions

For testing all-ceramic materials, dynamic loading is indispensable to draw valid conclusions on clinical performance of all-ceramic molar crowns. A sinusoidal profile is advisable, while a gradual increase of the force amplitude does not significantly affect the results.

Keywords: Ceramic, Dynamic loading, Fracture load, Force profile

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(08)00061-4

doi:10.1016/j.dental.2008.02.019

Dental Materials
Volume 24, Issue 10 , Pages 1352-1361, October 2008