Dental Materials
Volume 24, Issue 9 , Pages 1207-1211, September 2008

The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use

  • Q.Y. Wang

      Affiliations

    • Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001, China
  • ,
  • Y.F. Zheng

      Affiliations

    • Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001, China
    • Department of Advanced Materials and Nanotechnology, College of Engineering, Peking University, Beijing 100871, China
    • Corresponding Author InformationCorresponding author at: Department of Advanced Materials and Nanotechnology, College of Engineering, Peking University, Beijing 100871, China. Tel.: +86 10 6276 7411; fax: +86 10 6276 7411.

Received 27 March 2007; accepted 17 January 2008.

Abstract 

Objectives

The aim of this study was to investigate the electrochemical behavior of Ti50Ni47.2Co2.8 alloy in deaerated artificial saliva solutions with binary NiTi alloy as reference and to characterize the composition and structure of the passive film after polarization tests.

Methods

The corrosion behavior of NiTiCo alloy was systematically studied by open circuit potential, potentiodynamic and potentiostatic techniques. The surface characterization after anodic polarization tests were demonstrated by XPS. The electrolytes were maintained at 37°C by immersing the test cell in water bath. 500mV vs. SCE was applied on the samples for potentiostatic tests. The metal ions concentration was measured by ICP/OES.

Results

Potentiodynamic and potentiostatic tests results showed that the corrosion behavior of NiTiCo was similar to that of NiTi alloy. With the increase of pH value of the electrolytes, both corrosion potential (Ecorr) and pitting corrosion potential (Eb) decreased. XPS results revealed that the outmost passive film consisted mainly of TiO2 which were identical with that of NiTi alloy. The Ni ion release amount of NiTiCo was very close to that of NiTi alloy as examined by ICP/OES. Neither Ti nor Co ion was detected due to the detection limitation.

Significance

The corresponding relationship between corrosion behavior and pH value of the artificial saliva should be taken into consideration during the application of orthodontic wires. The addition of Co had little effect on the corrosion behavior of NiTi as well as the formation of the passive film.

Keywords: Shape memory alloy, Dental material, NiTi, NiTiCo, XPS, Electrochemical behavior, Corrosion resistance

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(08)00032-8

doi:10.1016/j.dental.2008.01.011

Dental Materials
Volume 24, Issue 9 , Pages 1207-1211, September 2008