Dental Materials
Volume 24, Issue 8 , Pages 1043-1049, August 2008

Minimal exposure time of different LED-curing devices

  • Anke Schattenberg

      Affiliations

    • Department of Operative Dentistry, Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131 Mainz, Germany
    • Corresponding Author InformationCorresponding author. Tel.: +49 6131 177247; fax: +49 6131 173406.
  • ,
  • Dana Lichtenberg

      Affiliations

    • Department of Operative Dentistry, Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131 Mainz, Germany
  • ,
  • Elmar Stender

      Affiliations

    • Institute for Dental Material Sciences and Technology, Johannes Gutenberg-University Mainz, Germany
  • ,
  • Brita Willershausen

      Affiliations

    • Department of Operative Dentistry, Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131 Mainz, Germany
  • ,
  • Claus-Peter Ernst

      Affiliations

    • Department of Operative Dentistry, Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131 Mainz, Germany

Received 1 March 2007; accepted 4 December 2007.

Abstract 

Objectives

The purpose of the study was to investigate the shortest possible exposure time of different LED-curing devices for five different resin composites in a clinically relevant in vitro-model, where a 7mm distance from the light guide tip to the bottom side of the cavity was compiled.

Methods

Resin composite samples (Tetric EvoCeram A3, Filtek Supreme XT A3B, Premise A3, CeramX Mono M5, QuiXfil) were filled in three increments of 2mm thickness each in stainless steel moulds (Ø=5mm, h=6mm, n=9). The samples were incrementally exposed to different blue LED-curing devices (Bluephase, Bluephase C8, Bluephase 16i/Ivoclar Vivadent, L.E.Demetron II/sds Kerr, Elipar FreeLight 2/3M ESPE, Smartlite PS/DENTSPLY, Translux Power Blue/Heraeus) according to the manufacturer's recommendations at a distance of 7mm from the bottom of the cavity to simulate a class II-curing situation.

Surface hardness was measured (Zwick Z2.5/TS1S) 10min post-exposure at the bottom surfaces of the resin sample. A bottom/top-surface hardness ratio of 80% of a reference sample (2mm thickness, 40s), was defined as clinically acceptable for safe curing. A descriptive statistical analysis was carried out.

Results

The curing devices Bluephase, Bluephase C8, Smartlite PS and Translux Power Blue could cure all composite resins investigated sufficiently in the exposure time recommended by the manufacturers (10–20s). The curing device Bluephase 16i and L.E.Demetron II only cured the composite Quixfil sufficiently in the exposure time recommended by the manufacturer. FreeLight 2+ allowed a 10s exposure time for all materials except Ceram X Mono (20s).

Significance

When incrementally exposed, all resin composites investigated were polymerized sufficiently at a maximum of 20s exposure time.

Keywords: Dental material, LED-curing device, Resin composite, Minimal exposure time

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(07)00286-2

doi:10.1016/j.dental.2007.12.001

Dental Materials
Volume 24, Issue 8 , Pages 1043-1049, August 2008