Dental Materials
Volume 24, Issue 7 , Pages 908-914, July 2008

Correlation between ceramics translucency and polymerization efficiency through ceramics

Department of Restorative Dentistry, Dental School of the Ludwig-Maximilians-University, Goethestreet 70, 80336 Munich, Germany

Received 2 February 2007; received in revised form 9 November 2007; accepted 9 November 2007.

Abstract 

Objectives

The aim of this study was to analyse the effects of curing with a high intensity curing unit for different exposure times, for different ceramic types, thicknesses and corresponding different ceramic translucencies. The relationship between ceramic translucency and hardness, as well as the critical translucency value for sufficient curing were also determined.

Methods

All these effects were expressed in terms of Vickers hardness measured with an automatic micro hardness indenter on thin luting composite films (Variolink II), stored for 24h in distilled water at 37°C. Two preliminary studies determined the time necessary to achieve maximum hardness in the luting composite, with and without an additional chemical catalyst. The main study aimed to estimate the effect on luting composite hardness, without an additional chemical catalyst, of the following parameters: curing time (5, 10 and 15s), ceramic thickness (0.5, 1, 2 and 3mm), ceramic type (two leucite-reinforced and two lithium disilicate glass-ceramics) and ceramic translucency (TP), measured using a reflection spectrophotometer as a function of wavelength.

Results

The minimum curing time necessary to achieve maximum hardness in the luting composite was 15s for both groups, with and without an additional chemical catalyst. However, dual curing caused a hardness enhancement of ca. 50%. The two leucite-reinforced glass-ceramics did not reduced the hardness of the luting composite up to a ceramic thickness of 2mm, whereas the more dense lithium disilicate glass-ceramics had already caused this effect at a thickness of 1mm. ANOVA analyses revealed that the greatest effect on the luting composite hardness resulted from the curing time (eta square=0.62) followed by translucency (eta square=0.32 TP650nm and 0.28 for TP470nm), ceramic type (eta square=0.17) and ceramic thickness (eta square=0.03).

Significance

High-power curing units are not able to consistently reduce the exposure time. In both systems, at least 15s were necessary to properly cure the luting composite. Furthermore, the effect of light activation on the dual curing luting composite cannot be neglected.

Keywords: Hardness, Translucency, Luting composite, Ceramics

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(07)00259-X

doi:10.1016/j.dental.2007.11.006

Dental Materials
Volume 24, Issue 7 , Pages 908-914, July 2008