Dental Materials
Volume 24, Issue 6 , Pages 773-777, June 2008

High-resolution non-destructive 3D interrogation of dentin using X-ray nanotomography

  • Charles R. Parkinson

      Affiliations

    • GlaxoSmithKline Research and Development, St. George's Avenue, Weybridge, Surrey KT13 0DE, UK
    • Corresponding Author InformationCorresponding author. Tel.: +44 1932 822218; fax: +44 1932 822100.
  • ,
  • Alexander Sasov

      Affiliations

    • SkyScan, Kartuizersweg 3B, B-2550 Kontich, Belgium

Received 23 February 2007; received in revised form 6 August 2007; accepted 11 September 2007.

Abstract 

Objectives

Dentin, a calcareous material sandwiched between the pulp and the enamel in the tooth structure contains highly orientated tubules. As a result of enamel erosion, gum recession, physical trauma or caries the dentin tubules can become patent to the oral cavity. It has been demonstrated in vivo that dentinal fluid flows out of the tubule lumen into the oral cavity and it has been postulated that alterations in fluid flow form the basis of dentin hypersensitivity. In order to better understand the mode of action of desensitising occlusion-based agents the ability to interrogate dentin non-destructively is paramount. Destructive analysis of the tooth structure may yield subtle artifacts leading to erroneous conclusions or inhibit the accurate assessment of the relationship between an occluding agent and the internal dentin morphology. This paper describes the use of a novel and accessible, non-invasive, high-focused X-ray computer tomographic technique for analysis of the dentin substructure.

Methods

Dentin slices, ca. 300μm3 in size, were taken from the coronal section of unerupted human third molars and etched in citric acid to reveal the open tubule structure. Samples were analyzed, in their dry state, using the Skyscan 2011 nanoCT system.

Results

Numerous, homogeneously dispersed elliptical features, distinguished by their contrast and hence low-mineral density, were observed. These features are observed to be approximately 2–5μm in diameter at a density equivalent to 106cm−2. 2D CT re-slices demonstrate that these circular features form highly orientated cylindrical manifestations extending throughout the sample.

Significance

Ultra-high-resolution X-ray computed tomography has been shown to be a powerful new technique for interrogating the submicron tubular structure of dentin non-destructively.

Keywords: Dentin, Tubules, Structural properties, Nanotomography, Hypersensitivity

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(07)00226-6

doi:10.1016/j.dental.2007.09.003

Dental Materials
Volume 24, Issue 6 , Pages 773-777, June 2008