Magnetic susceptibility and electrical conductivity of metallic dental materials and their impact on MR imaging artifacts

  • Jana Starčuková

      Affiliations

    • Institute of Scientific Instruments of the ASCR, v.v.i., Academy of Sciences of the Czech Republic, Královopolská 147, 612 64 Brno, Czech Republic
    • Corresponding Author InformationCorresponding author. Tel.: +420 541 514 247; fax: +420 541 514 402.
  • ,
  • Zenon Starčuk Jr.

      Affiliations

    • Institute of Scientific Instruments of the ASCR, v.v.i., Academy of Sciences of the Czech Republic, Královopolská 147, 612 64 Brno, Czech Republic
  • ,
  • Hana Hubálková

      Affiliations

    • Charles University, First Medical Faculty, Department of Stomatology, Prague, Czech Republic
  • ,
  • Igor Linetskiy

      Affiliations

    • Charles University, First Medical Faculty, Department of Stomatology, Prague, Czech Republic

Received 5 January 2007; received in revised form 31 July 2007; accepted 31 July 2007.

Abstract 

Objectives

The aim of this study was to test the hypothesis that dental materials vary significantly in MR-relevant material parameters—magnetic susceptibility and electrical conductivity, and that knowledge of these parameters may be used to estimate the quality of MR imaging in the presence of devices made of such materials.

Methods

Magnetic susceptibility, electrical conductivity and artifacts were evaluated for 45 standardized cylindrical samples of dental alloys and amalgams. Magnetic susceptibility was determined by fitting the phase of gradient-echo MR images to numerically modeled data. Electrical conductivity was determined by standard electrotechnical measurements. Artifact sizes were measured in spin-echo (SE) and gradient-echo (GE) images at 1.5T according to the standards of the American Society for Testing and Materials.

Results

It has been confirmed that dental materials differ considerably in their magnetic susceptibility, electrical conductivity and artifacts. For typical dental devices, magnetic susceptibility differences were found of little clinical importance for diagnostic SE/GE imaging of the neck and brain, but significant for orofacial imaging. Short-TE GE imaging has been found possible even in very close distances from dental devices made of amalgams, precious alloys and titanium alloys. Nickel–chromium and cobalt–chromium artifacts were found still acceptable, but large restorations of aluminum bronzes may preclude imaging of the orofacial region. The influence of electrical conductivity on the artifact size was found negligible.

Significance

MR imaging is possible even close to dental devices if they are made of dental materials with low magnetic susceptibility. Not all materials in current use meet this requirement.

Keywords: Metallic dental materials, Dental alloys, Amalgams, MR imaging, Magnetic susceptibility, Electric conductivity, Image artifact

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(07)00199-6

doi:10.1016/j.dental.2007.07.002

Dental Materials
Volume 24, Issue 6 , Pages 715-723, June 2008