Dental Materials
Volume 24, Issue 5 , Pages 584-593, May 2008

Hybridization quality in cervical cementum and superficial dentin using current adhesives

  • Yang Yuan

      Affiliations

    • Department of Cariology and Operative Dentistry, Tokyo Medical and Dental University, Tokyo, Japan
    • Center of Excellence Program, FRMDRTB at TMDU, Tokyo, Japan
    • Corresponding Author InformationCorresponding author at: 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan. Tel.: +81 3 5803 5483; fax: +81 3 5803 0195.
  • ,
  • Yasushi Shimada

      Affiliations

    • Department of Cariology and Operative Dentistry, Tokyo Medical and Dental University, Tokyo, Japan
  • ,
  • Shizuko Ichinose

      Affiliations

    • Instrumental Analysis Research Center, Tokyo Medical and Dental University, Tokyo, Japan
  • ,
  • Junji Tagami

      Affiliations

    • Department of Cariology and Operative Dentistry, Tokyo Medical and Dental University, Tokyo, Japan
    • Center of Excellence Program, FRMDRTB at TMDU, Tokyo, Japan

Received 13 September 2006; accepted 31 May 2007.

Abstract 

Objectives

The aim of this research was to determine the hybridization quality of adhesives to gingival cementum and close superficial dentin using both total-etch and self-etch, one-step and two-step adhesives in vitro.

Methods

Five adhesive systems were used and evaluated in this study; three kinds of two-step adhesives (total-etch—Single Bond and self-etch—Clearfil SE Bond and Clearfil Protect Bond) and two one-step adhesives (Clearfil S3 Bond, G Bond). Fifteen extracted intact human third molars were used in this study. A diagonal cut which was approximately 45° to the long axis of the roots, with the initiating point located 2mm below the buccal enamel–cementum junction and ascending towards the pulp chamber was prepared on each tooth. Flat cervical cementum and dentin surfaces were ground with wet 600-grit silicon carbide paper, and bonded with one of the adhesives and finished by applying a flowable resin composite. After 24h storage at 37°C in water, the bonded assemblies were sectioned into approximately 1mm thick slabs. Two central slabs from each tooth were chosen. One slab was totally demineralized in 0.5M EDTA and the other was not demineralized and immersed into 50% (w/v) solution of ammoniacal silver nitrate for 24h, and successively exposed to photodeveloping solution for 8h. The specimens were then processed for TEM observation. Both the stained demineralized silver unchallenged and unstained non-demineralized silver challenged resin–cervical cementum/proximal superficial dentin interface were observed and evaluated under a transmission electron microscope.

Results

The nanoleakage pathway and extent vary among the different adhesives used and also between the resin–cementum interface and resin–dentin interface. Two-step self-etch adhesives showed better hybridization quality both in cementum and proximal superficial dentin as compared to those of two-step total-etch adhesive and one-step self-etch adhesives.

Significance

Two-step self-etch adhesives may provide a better sealing in cervical cementum and the proximal superficial dentin region.

Keywords: Gingival cementum, Superficial dentin, Nanoleakage, Hybrid layer, TEM

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(07)00158-3

doi:10.1016/j.dental.2007.05.020

Dental Materials
Volume 24, Issue 5 , Pages 584-593, May 2008