Dental Materials
Volume 23, Issue 11 , Pages 1405-1411, November 2007

Dentinal fluid flow and cuspal displacement in response to resin composite restorative procedures

Department of Restorative Dentistry, School of Dental Science, The University of Melbourne, 720 Swanston Street, Melbourne, Victoria 3010, Australia

Received 7 October 2005; received in revised form 12 July 2006; accepted 16 November 2006.

Abstract 

Objectives

The aim of this study was to correlate the rate and magnitude of dentinal fluid flow (DFF) with cuspal displacement in response to resin composite restorative procedures.

Methods

Ten extracted human maxillary premolar teeth with an extensive MOD cavity preparation were connected to an automated fluid flow measurement apparatus (Flodec), and a direct current differencial transformer (DCDT) was attached to each cusp. The rate, magnitude and direction of DFF and cuspal displacement were recorded simultaneously in response to each stage of resin composite restorative procedures.

Results

Cuspal displacement and DFF in outward and inward directions accompanied each stage of the procedures. Drying produced rapid cuspal contraction. Bonding caused slight cuspal expansion, whereas light curing of resin induced gradual but extensive cuspal contraction, which persisted following light curing. During baseline outward DFF was low and increased slightly during etching. In contrast, substantial outward DFF occurred during drying. Light curing of the bonding agent and the resin composite produced inward DFF. Following light curing, an outward DFF began and continued for atleast 15min.

Significance

The large, rapid fluid movement and cuspal displacement during restoration, and the prolonged outward fluid flow post-curing have implications for post-operative sensitivity. While mechanical stresses within dentin associated with cuspal displacement appear capable of inducing DFF, the net fluid movement is the result of complex interactions either directly or indirectly of several stimuli (thermal, evaporation, osmotic, and possibly mechanical).

Keywords: Dentinal fluid flow (DFF), Cuspal displacement, Resin composite restorative procedures

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(06)00326-5

doi:10.1016/j.dental.2006.11.029

Dental Materials
Volume 23, Issue 11 , Pages 1405-1411, November 2007