Deformation of phosphate-bonded investment materials at elevated temperatures

  • Andrzej S. Juszczyk

      Affiliations

    • Department of Fixed and Removable Prosthodontics, King's College London Dental Institute at Guy's, King's College and St Thomas’ Hospitals, King's College London, UK
    • Corresponding Author InformationCorrespondence to: Department of Prosthodontics, King's College London Dental Institute at Guy's, King's College and St Thomas’ Hospitals, Floor 20, Guys Tower, Guys Hospital, London Bridge, London SE1 9RT, UK. Tel.: +44 2071881862; fax: +44 2071881857.
  • ,
  • David R. Radford

      Affiliations

    • Department of Fixed and Removable Prosthodontics, King's College London Dental Institute at Guy's, King's College and St Thomas’ Hospitals, King's College London, UK
  • ,
  • Richard V. Curtis

      Affiliations

    • Department of Dental Biomaterials Science, King's College London Dental Institute at Guy's, King's College and St Thomas’ Hospitals, King's College London, UK

Received 11 July 2005; received in revised form 2 December 2005; accepted 9 March 2006.

Abstract 

Objectives

To determine deformation in phosphate-bonded investment (PBI) materials for “in-service conditions” and to investigate the influence of air bubble pores on deformation at 900°C.

Methods

Surviving high and low strain-rate disc-rupture strength test samples were assessed for deformation. A dental centrifugal casting machine and a dental superplastic-forming machine were used to apply the loads. An indirect technique was used to measure the deformation of investment diaphragms with both a wide pore size distribution and with very low porosity for four investment materials. A total of 128 high strain-rate and 29 low strain-rate samples were investigated. A one-way analysis of variance was carried out.

Results

All but one of the high strain-rate test samples showed measurable deformation. All of the low strain-rate test samples containing pores showed measurable deformation. Six out of 14 samples, in which pores had been eliminated, showed no deformation. There was no statistically significant difference in deformation between samples with no pores and those with a large pore size distribution for either the high or low strain-rate tests (P>0.05).

Significance

PBI must survive all forming procedures without deformation if the resultant prosthesis is to fit. One hundred micrometres is generally recognized as the acceptable tolerance of fit for removable metal-based prostheses. The vast majority of deformations measured during this investigation were considerably greater than 100μm.

Keywords: Phosphate-bonded investment, Plastic deformation, Elevated temperatures

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(06)00105-9

doi:10.1016/j.dental.2006.03.017

Dental Materials
Volume 23, Issue 5 , Pages 579-585, May 2007