Dental Materials
Volume 23, Issue 3 , Pages 288-295, March 2007

Influence of cavity dimension and restoration methods on the cusp deflection of premolars in composite restoration

Department of Conservative Dentistry and Dental Research Institute, College of Dentistry, Seoul National University, 28-2 Yeongeon-Dong, Jongro-Gu, Seoul 110-749, South Korea

Received 19 April 2005; received in revised form 12 December 2005; accepted 10 January 2006.

Abstract 

Objectives

The aim of this study was to measure the cusp deflection by polymerization shrinkage during composite restoration for mesio-occluso-distal (MOD) cavities in premolars, and to examine the influence of cavity dimension, C-factor and restoration method on the cusp deflection.

Methods

Thirty extracted maxillary premolars of similar size were prepared with four different sizes of MOD cavity, and divided into six groups. The width and depth of the pulpal wall of the cavity were as follows: group 1: 1.5×1mm, group 2: 1.5×2mm, group 3: 3×1mm, and groups 4–6: 3×2mm. Groups 1–4 were restored using a bulk filling with a composite. Group 5 was restored incrementally, and group 6 was restored with an indirect composite inlay. Cusp deflections were measured using LVDT transducers. The cusp deflections were compared between groups using ANOVA and Scheffe tests, and a correlation analysis was done.

Results

The cusp deflections of groups 1–4 were 12.1 (2.2), 17.2 (1.9), 16.2 (0.8) and 26.4 (4.2)μm, respectively. There was a strong positive correlation between the length cubed divided by the thickness cubed of the remaining cusp (L3/T3) and cusp deflection. The C-factor was related to the % flexure (100×cusp deflection/cavity width). The cusp deflections of groups 5 and 6 were 17.4 (2.0) and 17.9 (1.4)μm, respectively, which were much lower values than those of group 4.

Significance

: The cusp deflection increased with increasing cavity dimension and C-factor. Use of an incremental filling technique or an indirect composite inlay restoration could reduce the cuspal strain.

Keywords: Cusp deflection, Polymerization shrinkage, Composites, C-factor, Bulk filling, Incremental filling, Indirect composite inlay

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(06)00037-6

doi:10.1016/j.dental.2006.01.025

Dental Materials
Volume 23, Issue 3 , Pages 288-295, March 2007