« Previous
Next »
Dental Materials
Volume 22, Issue 8
, Pages 712-734
, August 2006
How to qualify and validate wear simulation devices and methods
References
- European Community. Council directive concerning medical devices. Directive 93/42 EEC 1993.
- FDA, Center for Devices and Radiological Health. Safety tests (chemical substances, medical devices such as implants, etc.). Directive No. 21 CFR 58-1978.
- FDA, Center for Devices and Radiological Health. Guideline on general principles of process validation. No. 820 1987.
- European Community. Tests on chemical substances. Directive 87/18-20/EEC-1987.
- FDA, Center for Devices and Radiological Health. Good Laboratory Practice (GLP) (PART 58 52 FR 33780, 1978. last revision 2004); 1978.
- ISO. Dental materials—guidance on testing of wear. Part 1. Wear by tooth brushing. Technical Specification 1999; No. 14569-1.
- ISO. Dental materials—guidance on testing of wear. Part 2. Wear by two-and/or three body contact. Technical Specification 2001; No. 14569-2.
- . Interactions between dental amalgams and the oral environment. Adv Dent Res. 1992;6:100–109
- . Impact of nocturnal bruxism on mercury uptake from dental amalgams. Eur J Oral Sci. 1997;105:251–257
- . Biocompatibility of micro- and nano-particles in the colon. Part II. Biomaterials. 2004;25:385–392
- . Biocompatibility of micro- and nanoparticles. Part I. In liver and kidney. Biomaterials. 2002;23:2381–2387
- . Verschleissanalyse und -quantifizierung von Füllungsmaterialien in vivo und in vitro. Shaker Verlag: Aachen; 1998;
- . Degradability of dental ceramics. Adv Dent Res. 1992;6:82–89
- . Veterans Administration Cooperative Studies Project No. 147. Part IV. Biocompatibility of base metal alloys. J Prosthet Dent. 1987;58:1–5
- . Current view of risk factors for periodontal diseases. J Periodontol. 1996;67:1041–1049
- . Predictors of signs and symptoms of temporomandibular disorders: a 20-year follow-up study from childhood to adulthood. Acta Odontol Scand. 2002;60:180–185
- . No association between incisal tooth wear and temporomandibular disorders. J Prosthet Dent. 2002;87:197–203
- . The prevalence of dental attrition and its association with factors of age, gender, occlusion, and TMJ symptomatology. J Dent Res. 1988;67:1323–1333
- Risk factors for high occlusal wear scores in a population-based sample: results of the Study of Health in Pomerania (SHIP). Int J Prosthodont. 2004;17:333–339
- . Association of malocclusion and functional occlusion with temporomandibular disorders (TMD) in adults: a systematic review of population-based studies. Quintessence Int. 2004;35:211–221
- . Occlusal adjustment for treating and preventing temporomandibular joint disorders. The Cochrane Database of Systematic Reviews. 2002;
- . Movement of teeth adjacent to posterior bounded edentulous spaces. J Dent Res. 2001;80:2021–2024
- . The consequences of not replacing a missing posterior tooth. J Am Dent Assoc. 2000;131:1317–1323
- . Dental composites/glass ionomers: clinical reports. Adv Dent Res. 1992;6:65–77
- . Direct resin composite inlays/onlays: an 11-year follow-up. J Dent. 2000;28:299–306
- . Changes in self-reported incidence of nocturnal bruxism in college students: 1966–2002. Percept Mot Skills. 2003;97:777–778
- . An overview of bruxism and its management. Dent Clin North Am. 1997;41:229–241
- . Longevity of restorations in posterior teeth and reasons for failure. J Adhes Dent. 2001;3:45–64
- . Longevity of direct resin composite restorations in posterior teeth. Clin Oral Invest. 2003;7:63–70
- . Evaluation of proximal contacts of posterior composite restorations with 4 placement techniques. J Can Dent Assoc. 2003;69:162–167
- . Wear resistance of some prosthodontic materials in vivo. Acta Odontol Scand. 1993;51:99–107
- CRA. Restorative resins: current generation Class 2 resin status report #3. 2-year clinical performance. CRA Newsletter 1996;20:1–3.
- . Three-year follow-up of five posterior composites: in vivo wear. J Dent. 1993;21:74–78
- . Comparison of laboratory and clinical wear rates of resin composites. Quintessence Int. 2004;35:269–274
- Clinical wear performance of eight experimental dental composites over three years determined by two measuring methods. Eur J Oral Sci. 2001;109:273–281
- CRA. Posterior full crowns 2001. Part 2. Resin crowns, 4 year clinical status. CRA Newsletter 2001;25:1–3.
- . Clinical challenges and the relevance of materials testing for posterior composite restorations. Dent Mater. 2005;21:9–20
- . Composite resin fillings and inlays. An 11-year evaluation. Clin Oral Invest. 2003;7:71–79
- . Clinical evaluation of compomer in primary teeth: 1-year results. J Am Dent Assoc. 1997;128:1088–1096
- . Clinical evaluation of Dyract AP restorative in permanent molars: 2-year results. Am J Dent. 2002;15:403–406
- . Buonocore Memorial Lecture. Review of the clinical survival of direct and indirect restorations in posterior teeth of the permanent dentition. Oper Dent. 2004;29:481–508
- . In vivo measurement of antagonist tooth wear opposing ceramic bridges. J Dent Res. 2000;79:172;[Abstract No. 232]
- . In vivo wear of enamel by a lithia-disilicate-based core ceramic used for posterior FPDs: first-year results. J Dent Res. 2003;[Abstract 2633]
- . Clinical performance of experimental glass-ceramic posterior crowns: 3D measurement of clinical wear. J Dent Res. 2002;[Abstract 1697]
- Materials ACoD. Posterior composite resins: an update. Council on Dental Materials, Instruments, and Equipment. J Am Dent Assoc 1986;113:950–1.
- . Qualitätsleitlinien in der Zahnmedizin. Bern: SSO; 2000;
- . Feedback control during mastication of solid food textures—a clinical-experimental study. J Prosthet Dent. 1998;80:330–336
- . Effects of sample hardness on human chewing force: a model study using silicone rubber. Arch Oral Biol. 2004;49:805–816
- . Control of elevator muscle activity during simulated chewing with varying food resistance in humans. J Neurophysiol. 1992;68:933–944
- . Effects of ethnicity, gender and age on clenching force and load distribution. Clin Oral Invest. 2001;5:63–68
- . Association of salivary flow rates with maximal bite force. J Dent Res. 2000;79:1560–1565
- . Chewing movements in relation to border movements at the first molar. J Prosthet Dent. 1981;46:308–322
- . In-Vitro-Testverfahren zur Evaluation Dentaler Restaurationssysteme. 1. Computergesteuerter Kausimulator. Schweiz Monatsschr Zahnmed. 1990;100:953–960
- . Development of an artificial oral environment for the testing of dental restoratives: bi-axial force and movement control. J Dent Res. 1983;62:32–36
- . An artificial oral environment for testing dental materials. IEEE Trans Biomed Eng. 1991;38:339–345
- . An in vitro device for predicting clinical wear. Quintessence Int. 1989;20:755–761
- . In vitro wear device for determining posterior composite wear. J Am Dent Assoc. 1999;130:1347–1353
- Zipprich H, Rütters CB, Lauer H-C. Kausimulation—was simulieren wir wirklich? Jahrestagung der Deutsche Gesellschaft für zahnärztliche Prothetik und Werkstoffkunde, Kiel 2004; Nr. 23.
- . Wear of ten dental restorative materials in five wear simulators—results of a round robin test. Dent Mater. 2005;21:304–317
- . Abrasive wear of resin composites as related to finishing and polishing procedures. Dent Mater. 2005;21:641–648
- . Endodontic leakage studies reconsidered. Part II. Statistical aspects. Int Endod J. 1993;26:44–52
- . Water and abrasive effects on three-body wear of composites. J Dent Res. 1991;70:1074–1081
- . Chewing pressure vs. wear of composites and opposing enamel cusps. J Dent Res. 1992;71:1525–1529
- . Effects of load and antagonist shape on wear of composite. J Dent Res. 2003;[Abstract 825]
- . Effect of contact area size on enamel and composite wear. J Dent Res. 1992;71:1413–1416
- . Effect of antagonist diameter on in vitro wear of dental composite. J Dent Res. 2003;[Abstract 954]
- . The influence of antagonist standardization on wear. J Dent Res. 1999;78:713–719
- . Zahnfarbene adhäsive Füllungen im Seitenzahnbereich. Zürich: Eigenverlag PPK; 2001;
- . A two-body frictional wear test. J Dent Res. 1994;73:1546–1553
- . Wear characteristics in a two-body wear test. Dent Mater. 1994;10:269–274
- . Factors effecting dental composite wear in vitro. J Biomed Mater Res. 1997;38:303–313
- . Potential countersample materials for in vitro simulation wear testing. Dent Mater. 2002;18:246–254
- Ferracane JL, Egge A, Heintze SD. Comparison of antagonists for producing wear of dental composites in the OHSU oral wear simulator. Academy of Dental Materials Annual Meeting; 2003.
- . How heat treatment and thermal cycling affect wear of composite resin inlays. J Am Dent Assoc. 1994;125:1467–1472
- . Thermocycling—the effects upon the compressive strength and abrasion resistance of three composite resins. J Oral Rehabil. 1994;21:533–543
- . Influence of thermal cycling on OCA wear of composite restoratives. Oper Dent. 2001;26:349–356
- . The influence of different abrasion media o three-body-wear of composites. J Dent Res. 1995;74;[Abstract Nr. 625]
- . In vitro wear of composite veneering materials. J Mater Sci. 2002;37:425–429
- . Predictors of clinical wear of restorative dental composite materials. Biomed Mater Eng. 1993;3:167–174
- . Correlation between fracture properties and clinical performance of composite resins in Class IV cavities. Aust Dent J. 1990;35:46–49
- . Mechanical properties and wear behavior of light-cured packable composite resins. Dent Mater. 2000;16:33–40
- . Salivary factors in vomiting bulimics with and without pathological tooth wear. Caries Res. 1996;30:361–366
- . Evaluation of composite wear with a new multi-mode oral wear simulator. Dent Mater. 1996;12:218–226
- . In vitro wear of packable dental composites. Compend Contin Educ Dent Suppl. 1999;S60–S66
- . Evaluation of seven commercial composites using new in vitro wear simulator. J Dent Res. 2002;[Abstract Nr. 2683]
- Materials ACoD. Obstacles to the development of a standard for posterior composite resins. Council on Dental Materials, Instruments, and Equipment. J Am Dent Assoc 1989;118:649–51.
- . Mesio-occlusodistal amalgam restorations: quantitative in vivo data up to 4 years. A data base for the development of amalgam substitutes. Quintessence Int. 1994;25:185–190
- . In-vitro-Testverfahren zur Evaluation dentaler Restaurationssysteme. 3. Korrelation mit In-vivo-Resultaten. Schweiz Monatsschr Zahnmed. 1990;100:1445–1449
- . Occlusal wear simulation with the ACTA wear machine. J Dent. 1994;22:S21–S27
- . Comparison of three standards for quantifying occlusal loss of composite restorations. Dent Mater. 1990;6:60–62
- . Composite restoration wear analysis: conventional methods vs. three-dimensional laser digitizer. J Am Dent Assoc. 2000;131:1472–1477
- . Apparatus for automated, non-contact measurements of surface changes. J Dent Res. 1990;69:126;[Abstract 140]
- . Measurement of change in surface contour by computer graphics. Dent Mater. 1985;1:27–30
- . Degradation of Dental Polymers. Basel: Karger; 1987;
- . F.L. Eine neue Methode zur dreidimensionalen Verschleissmessung. Schweiz Med Zahnmed. 1994;104:147–157
- . A new optical 3-D device for the detection of wear. J Dent Res. 1997;76:1799–1807
- CRA. Two-year clinical comparison of Renamel Hybrid to 5 popular Class 2 resins. CRA Newsletter 2000;24:1–2.
- . Proximal wear rates by tooth position of resin composite restorations. J Dent. 1996;24:33–39
- . Determination of changes on tooth-colored cervical restorations in vivo using a three-dimensional laser scanning device. Eur J Oral Sci. 2000;108:233–238
- . A pilot clinical study on the Artglass system. J Dent Res. 1998;77:900;[Abstract No. 2150]
- . Quantitative evaluation of the wear resistance of posterior dental restorations: a new three-dimensional measuring technique. J Dent. 1984;12:252–267
- . Quantitative in vivo wear of human enamel. J Dent Res. 1989;68:1752–1754
- CRA. Posterior full crowns 2001. Part 3. 2-Year clinical performance of CAD-CAM copings & full crowns. CRA Newsletter 2001;25:1–3.
- Willytec. Multifunctional chewing simulator—instructions of use 2001;1–39.
- . The wear of dental amalgam in an artificial mouth: a clinical correlation. Dent Mater. 1985;1:238–242
- . The wear of a posterior composite in an artificial mouth: a clinical correlation. Dent Mater. 1986;2:235–240
- . Quantitative in vivo wear of posterior dental restorations: four-year results. J Dent Res. 1985;62:370;[Abstract No. 1759]
- . In vivo evaluation of four posterior composites: quantitative wear measurements and clinical behavior. Dent Mater. 1986;2:106–113
- . Zahnfarbene Restaurationen - Qualität. Potential und Indikationen. München: Carl Hanser; 1992;
- . Effect of abrasion medium on wear of stress-bearing composites and amalgam in vitro. J Dent Res. 1986;65:654–658
- . In vitro wear of direct and indirect nonhybrid composites. J Dent Res. 2005;[Abstract Nr. 3089]
- . An in vitro evaluation of a copolymerizable type of microfilled composite resin. Quintessence Int. 1994;25:59–64
- . In vitro wear of indirect composite restoratives. J Prosthet Dent. 2002;88:431–436
- . Mechanical properties and wear of restorative composites. J Dent Res. 2003;[Abstract Nr. 381]
- . Three-body wear of restorative composite materials. J Dent Res. 2003;[Abstract Nr. 957]
- . Mechanical properties of dental restoratives and their comparative flowables. J Dent Res. 2005;[Abstract Nr. 1844]
- . Annealing as a mechanism of increasing wear resistance of composites. Dent Mater. 1990;6:266–270
- . Wear resistance of various nano-structured composites. J Dent Res. 2002;[Abstract Nr. 3358]
- . In vitro wear of composite resins processed with various systems. J Dent Res. 2002;[Abstract Nr. 2578]
- . Attritional wear and abrasive surface alterations of composite resin materials in vitro. J Dent. 2002;30:119–127
- . Marginal integrity and wear of new resin composites in vitro. J Dent Res. 2005;[Abstract Nr. 279]
- . Wear and marginal adaptation of composite resin inlays. J Prosthet Dent. 1994;72:233–244
- . Dual-cure resin cements: in vitro wear and effect of quantity of remaining double bonds, filler volume, and light curing. Acta Odontol Scand. 1995;53:29–34
- . Two-body and three-body wear of glass ionomer cements. Int J Paediatr Dent. 2003;13:434–440
- . Mechanical properties and three-body wear of veneering composites and their matrices. J Biomed Mater Res A. 2004;69:65–69
- . Comparison of two- and three-body wear of glass-ionomers and composites. Eur J Oral Sci. 1996;104:132–137
- . Influence of shearing action of food on contact stress and subsequent wear of stress-bearing composites. J Dent Res. 1993;72:56–61
- . Wear rates of composites, an amalgam, and enamel under stress-bearing conditions. J Prosthet Dent. 1988;59:426–429
- . Influence of enzymes and plaque acids on in vitro wear of dental composites. Biomaterials. 1996;17:1327–1332
- . Wear and microhardness of different resin composite materials. Oper Dent. 2003;28:628–634
- . Hardness and in vitro wear of a novel ceramic restorative cement. Eur J Oral Sci. 2002;110:175–178
- . Wear resistance of dual-cured resin luting agents. Am J Dent. 1995;8:161–164
- . Silane treatment of filler and composite blending in a one-step procedure for dental restoratives. Biomaterials. 1994;15:1152–1156
- . The influence of admixing microfiller to small-particle composite resin on wear, tensile strength, hardness, and surface roughness. J Dent Res. 1989;68:489–490
- . The influence of dental alloys on three-body wear of human enamel and dentin in an inlay-like situation. Oper Dent. 2002;27:167–174
- . Early and long-term wear of conventional and resin-modified glass ionomers. J Dent Res. 1996;75:1613–1619
- . Evaluation of resin composite materials. Part I. In vitro investigations. Am J Dent. 2005;18:23–27
- . Wear of CAD/CAM ceramic inlays: restorations, opposing cusps, and luting cements. Quintessence Int. 1994;25:199–207
- . Wear of ceramic inlays, their enamel antagonists, and luting cements. J Prosthet Dent. 1993;69:425–430
- . Localized wear and marginal integrity of posterior resin composites. Am J Dent. 1993;6:199–203
- . Wear resistance of resin cements. Am J Dent. 1995;8:83–87
- . Evaluating the antagonistic wear of restorative materials when placed against human enamel. J Am Dent Assoc. 1996;127:74–80
- . Does the wear resistance of packable composite equal that of dental amalgam?. J Esthet Restor Dent. 2004;16:355–365
- . Enamel wear of modified porcelains. Am J Dent. 2000;13:315–323
- . Evaluation of wear: enamel opposing three ceramic materials and a gold alloy. J Prosthet Dent. 1997;77:523–530
- . Vertical height loss: an investigation of four restorative materials opposing enamel. J Prosthodont. 1999;8:252–257
- . Effect of gap dimension on wear resistance of luting agents. Am J Dent. 1995;8:149–151
- . In vitro wear of nano-composite denture teeth. J Prosthodont. 2004;13:238–243
- . Simulated enamel wear during occlusal contact. Am J Dent. 2004;17:373–377
- . Effect of filler size on wear resistance of resin cement. Odontology. 2001;89:41–44
- . Wear of luting materials with titanium retainer. Am J Dent. 2001;14:81–84
- . Wear of composite resin inlays and antagonistic enamel. Am J Dent. 1999;12:47–50
- . A new copolymerized composite resin system: a multiphased evaluation. Int J Periodont Restor Dent. 1995;15:482–495
- . Effect of organic peroxide additives on wear resistance of composite resin. Compend Contin Educ Dent. 1997;18:1006–10081009–11
- . Effect of an adhesive bonding system on wear resistance of resin composite restorations. Quintessence Int. 1997;28:687–693
- . Effect of particle variation on wear rates of posterior composites. Am J Dent. 1995;8:173–178
- . Effect of surface-penetrating sealant on wear resistance of luting agents. Quintessence Int. 1994;25:767–771
- . Three-body wear of light-activated composite veneering materials. J Prosthet Dent. 1995;73:233–239
- . Localized three-body wear of six types of composite resin veneering materials. J Prosthet Dent. 1993;70:207–213
- . The wear of dental porcelain in an artificial mouth. Dent Mater. 1986;2:214–219
- . Wear rates of artificial denture teeth opposed by natural dentition. J Clin Dent. 1993;4:43–47
- . Wear of enamel and veneering ceramics after laboratory and chairside finishing procedures. J Prosthet Dent. 1999;82:669–679
- . The wear of enamel opposing shaded ceramic restorative materials: an in vitro study. J Prosthet Dent. 1992;68:42–48
- . Enamel abrasion from ceramic orthodontic brackets under an artificial oral environment. Am J Orthod Dentofacial Orthoped. 1990;98:103–109
- . The wear of enamel when opposed by ceramic systems. Dent Mater. 1989;5:266–271
- . In vitro study of the wear characteristics of natural and artificial teeth. J Prosthet Dent. 1985;54:273–280
- . Filler features and their effects on wear and degree of conversion of particulate dental resin composites. Biomaterials. 2005;26:4932–4937
- . Effect of filler fraction and filler surface treatment on wear of microfilled composites. Dent Mater. 2002;18:1–11
- . In vitro wear of composite with varied cure, filler level, and filler treatment. J Dent Res. 1997;76:1405–1411
- . Wear and marginal breakdown of composites with various degrees of cure. J Dent Res. 1997;76:1508–1516
- . In vitro evaluation of the marginal degradation of dental composites under simulated occlusal loading. Dent Mater. 1999;15:262–267
- . Evaluation of cure, properties and wear resistance of Artglass dental composite. Am J Dent. 1998;11:214–218
- . In vitro wear simulation measurements of composite versus resin-modified glass ionomer luting cements for all-ceramic restorations. J Esthet Restor Dent. 2002;14:368–376
- . Relative wear of flowable and highly filled composite. J Prosthet Dent. 2005;93:153–157
- . Evaluation of wear resistance of dental resin composites with a 3D profilometer. J Biomed Mater Res B. 2004;71:414–420
- . Relative wear of enamel opposing low-fusing dental porcelain. J Prosthodont. 2003;12:168–175
- . Wear of enamel opposing low-fusing and conventional ceramic restorative materials. J Prosthodont. 2001;10:8–15
- . Influence of the antagonist material on the wear of different composites in two different wear simulators. Dent Mater. 2006;22:166–175
- . Wear of composite resin veneering materials in a dual-axis chewing simulator. J Oral Rehabil. 1999;26:372–378
- . Wear of aluminum oxide antagonists by commercially available composites and compomers. Am J Dent. 2004;17:285–290
- . Sliding wear of 19 commercially available composites and compomers. Dent Mater. 2004;20:277–285
PII: S0109-5641(06)00035-2
doi: 10.1016/j.dental.2006.02.002
© 2006 Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Dental Materials
Volume 22, Issue 8
, Pages 712-734
, August 2006
