Dental Materials
Volume 22, Issue 8 , Pages 702-711, August 2006

Intra-oral restorative materials wear: Rethinking the current approaches: How to measure wear

  • Ralph DeLong

      Affiliations

    • Corresponding Author InformationPresent address: Minnesota Dental Research Center for Biomaterials and Biomechanics, 16-212 Moos Health Sciences Tower, 515 Delaware St. SE, Minneapolis, MN 55455, USA. Tel.: +1 612 625 1409; fax: +1 612 626 1484.

Department of Restorative Sciences, University of Minnesota School of Dentistry, Minneapolis, MN, USA

Abstract 

Objective

To determine what wear parameter(s) have clinical relevance and what factors are important for accurate measurement of these parameters in vivo and in vitro.

Method

Describe biomechanical factors affecting mastication and the mechanics of wear. Investigate how they impact the wear of teeth and restorative materials. Based on this information, define the advantages and disadvantages of using volume, depth, and area parameters to quantify wear. Describe direct and indirect methods of measuring wear and point out advantages and disadvantages of each.

Results

The preferred parameter for quantifying wear is volume. It is independent of occlusal factors and is a measure of work done. If material and environmental factors remain constant, volume loss is linear with time. Depth and area have limited clinical value because of their dependence on occlusal factors; plus, they are not linear with time. When measuring wear the material of interest and the opposing material must be considered; especially if the opposing material is enamel. Wear is best measured by comparing sequential 3D images. Measuring systems should be calibrated with their error reported using sigma values rather means and standard deviations. The quality of the alignment of the sequential images should be included in the error analysis. Cost and availability of 3D imaging systems has severely limited their use in clinical studies.

Significance

Wear is an important consequence of occlusal interactions. If not controlled, wear could lead to poor masticatory function with a concomitant reduction in quality of life and possible deterioration of systemic health.

Keywords: Wear, Dental materials, 3D imaging, Scanning, Volume, Depth, Area, Contact area, Occlusal contact

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(06)00034-0

doi:10.1016/j.dental.2006.02.003

Dental Materials
Volume 22, Issue 8 , Pages 702-711, August 2006