Durability of the resin bond strength to zirconia ceramic after using different surface conditioning methods

  • Mona Wolfart

      Affiliations

    • Corresponding Author InformationCorresponding author at: Department of Prosthodontics, Propaedeutics and Dental Materials, University Hospital Schleswig-Holstein-Campus Kiel, Arnold-Heller-Str. 16,24105 Kiel, Germany. Tel.: +49 431 597 2874; fax: +49 431 587 2860.
  • ,
  • Frank Lehmann
  • ,
  • Stefan Wolfart
  • ,
  • Matthias Kern

Department of Prosthodontics, Propaedeutics and Dental Materials, Dental School, Christian-Albrechts-University at Kiel, Germany

Received 14 July 2005; accepted 30 November 2005.

Abstract 

Objectives

The purpose of this in vitro study was the evaluation of the bond strength and its durability of two composite resins to zirconia ceramic after using different surface conditioning methods.

Methods

Plexiglas tubes filled with composite resin were bonded to zirconia ceramic discs (Cercon) which were either in their original state as supplied by the manufacturer only cleaned in isopropanol or were cleaned with an air–powder–water spray with sodium hydrocarbonate solution or were air abraded (50μm Al2O3). Groups of 20 specimens each were bonded either with a conventional composite resin (Variolink II) or with a phosphate monomer (MDP)-containing resin (Panavia F) to the ceramic discs. Subgroups of 10 bonded specimens were stored in distilled water (37°C) for either 3 days or for 150 days. Additionally, the 150 days specimens were thermal cycled 37,500 times. Statistical analyses were conducted with the Wilcoxon rank sum test adjusted by Bonferroni–Holm.

Results

The initial tensile bond strength (TBS) for Variolink II ranged from 9.0 to 16.6MPa and were significantly lower (p0.05) than for Panavia F ranging from 18.7 to 45.0MPa. Air abrasion resulted in significantly higher TBS (p0.01) than the two other surface conditioning methods. After 150 days storage, only the air abraded specimens bonded with Panavia F showed high bond strengths of 39.2MPa, whereas most other specimens debonded spontaneously or showed very low bond strengths.

Significance

The use of the MDP-containing composite resin Panavia F on air abraded zirconia ceramic can be recommended as promising bonding method.

Keywords: Cercon, Zirconia ceramic, Composite resin, Tensile bond strength, Surface conditions

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(05)00356-8

doi:10.1016/j.dental.2005.11.040

Dental Materials
Volume 23, Issue 1 , Pages 45-50, January 2007