Dental Materials
Volume 22, Issue 10 , Pages 954-962, October 2006

Human pulp response to resin cements used to bond inlay restorations

  • Carlos A. de Souza Costa

      Affiliations

    • Department of Physiology and Pathology, Araraquara School of Dentistry, University of São Paulo State-UNESP, Rua Humaitá, 1680-CEP, 14801-903 Araraquara, São Paulo, Brazil
    • Corresponding Author InformationCorresponding author. Tel.: +1 55 16 3301 6477; fax: +55 16 3301 6488.
  • ,
  • Josimeri Hebling

      Affiliations

    • Department of Orthodontics and Pediatric Dentistry, School of Dentistry, University of São Paulo State-UNESP, Araraquara, São Paulo, Brazil
  • ,
  • Ros C. Randall

      Affiliations

    • 3M ESPE Dental Products, 3M Center, Building 0260-02-A-10, St. Paul, MN 55144-1000, USA

Received 8 June 2005; received in revised form 9 September 2005; accepted 27 October 2005.

Abstract 

Objective

The aim of this study was to evaluate the pulp response following cementation of inlays using two different resin cements.

Methods

Deep Class V cavities were prepared on the buccal surface of 34 sound human premolars. Impressions were taken and inlays were prepared which were cemented with the following luting materials—Group 1: Rely X™ Unicem (3M ESPE); Group 2: Variolink® II (Ivoclar Vivadent). In Group 3 (control), after lining the cavity floor with Dycal® (Dentsply Caulk) the inlays were cemented with Rely X™ Unicem. Four additional teeth were used as an intact control group. For Variolink® II, the adhesive system Excite was used as part of the cementation procedure. After 7 or 60 days, the teeth were extracted and processed for histological assessment.

Results

At 7 days, Rely X™ Unicem and Variolink® II system triggered in two samples a mild and moderate inflammatory response, respectively. At 60 days, the pulpal response decreased for both groups. A discrete persistent inflammatory response occurred in Group 2 in which displacement of resin components across the dentin tubules was observed. In the control group, normal histological characteristics were observed. The inflammatory response and tissue disorganization were related to the remaining dentin thickness between the cavity floor and the pulp tissue.

Significance

Techniques for inlay cementation using distinct luting cements may cause specific pulpal damage. Variolink® II associated with the adhesive system Excite cause more aggressive effects to the pulp–dentin complex than Rely X™ Unicem cement when both are used to cement inlay restorations.

Keywords: Biocompatibility, Resin cement, Dentin, Pulp, Luting cement

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(05)00311-8

doi:10.1016/j.dental.2005.10.007

Dental Materials
Volume 22, Issue 10 , Pages 954-962, October 2006