Dental Materials
Volume 22, Issue 4 , Pages 374-381, April 2006

In vitro fracture resistance of four-unit fiber-reinforced composite fixed partial dentures

Department of Prosthetic Dentistry, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany

Received 25 November 2004; accepted 7 April 2005.

Summary 

Objectives

The aim of this in vitro study was to investigate the influence of glass fiber-reinforcement on the fracture resistance of four-unit composite fixed partial dentures (FPDs) in the posterior region.

Methods

A total of 70 FPDs were fabricated of the composites Sinfony, Vita Zeta and Targis. With each material, 10 FPDs were made without glass fiber-reinforcement and 10 were reinforced with the new glass fiber system EverStick. In addition, 10 FPDs were fabricated of the material combination Targis/Vectris. After thermocycling, all FPDs were loaded until failure in a universal testing machine. The FPDs were then cut and cross-sectional areas were examined by scanning electron microscopy (SEM).

Results

The load to fracture of the fiber-reinforced FPDs lay between 615 and 1191N, which was significantly greater than the values found with unreinforced FPDs (between 178 and 307N). The highest values were found with the combinations Targis/Vectris (1191N) and Sinfony/EverStick (1137N). SEM showed that the FPDs with EverStick reinforcement not only exhibited fracture lines in the fiber-composite interface, but also more often in the area of the fiber-reinforcement than was the case with the FPDs with Vectris reinforcement. The load to fracture was not significantly dependent on fiber quantity or course of fracture.

Significance

It may be concluded that the fracture resistance of four-unit composite FPDs can be significantly raised by glass fiber frameworks (p<0.05). The reinforcement effect of EverStick depended significantly on the composite used (p<0.05).

Keywords: Dental material, Fiber-reinforcement, Composite, Fixed partial denture, FPD, Fracture resistance, In vitro

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(05)00188-0

doi:10.1016/j.dental.2005.04.040

Dental Materials
Volume 22, Issue 4 , Pages 374-381, April 2006