Dental Materials
Volume 22, Issue 1 , Pages 84-93, January 2006

Effect of fiber volume fraction and length on the wear characteristics of glass fiber-reinforced dental composites

Department of Mechanical, Industrial and Manufacturing Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA 02115, USA

Received 26 April 2004; received in revised form 14 January 2005; accepted 8 February 2005.

Summary 

Objective

The main objective of this study was to evaluate the wear characteristics of fiber-reinforced dental composites. Variables under investigation include the fiber weight percent added to the matrix as well as fiber length.

Methods

Dental specimens with glass fiber content of 2, 5.1, 5.7, and 7.6wt% with fiber length of either 1.5 or 3mm, were prepared by mixing an activated dental resin with commercial glass fibers. The specimens were then tested on a pin on disc setup, where the antagonist disc was manufactured of a similar fiber-reinforced composite with 5.1wt% fiber and fiber length of 3mm. The volume loss and coefficient of friction of the specimens was monitored periodically throughout testing. In addition, the wear surfaces of all specimens were evaluated using a scanning electron microscope.

Results

The specimens with 5.7wt% fibers and fiber length of 3mm performed better in this study compared to all other fiber-reinforced specimens under all load conditions. In fact, this specimen had a comparable wear rate to a particle-filled dental composite. For the fiber lengths considered, increasing the length of the fibers increased the wear resistance of the specimen. The coefficient of friction showed a good correlation with the wear resistance of specimens.

Significance

Fiber-reinforced composites demonstrated a high resistance to wear and may therefore be advantageous for dental applications, where high wear resistance is essential to functionality.

Keywords: Dental restoration, Fiber-reinforced composite, Wear, Fiber reinforcement, Pin on disk setup, Fiber volume fraction, Friction

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0109-5641(05)00133-8

doi:10.1016/j.dental.2005.02.011

Dental Materials
Volume 22, Issue 1 , Pages 84-93, January 2006